This site is designed to take advantage of CSS. If you are seeing this, CSS must not be available or enabled in your browser. Everything should still work, but won't be as pretty. :)



Screen calibration – step by step
This section shows step by step how to set up a screen
calibration. It bases on the typical 4c print calibration.
For the colour calibration, a printed gray wedge and a printed
colour wedge are required. The best choice is to get one from the
print shop where you usually place your print orders. The grayscale
wedge should show all grayscale steps from white to black at a length
of e.g. 10 cm. The colour wedge should show the four process colours
Cyan, Magenta, Yellow and Black Key (CMYK), e.g. in 2x2 cm square full
colour prints.
- It is a good idea to sleep well before you start the
calibration work. When you are tired, your eyes are tired, too, and
don't see colours like in normal state. Keep in mind that you are
going to define a monitor calibration for your own eyes only,
resulting in a subjective correct colour presentation which will not
be correct for your neighbor automatically, too. As you want to
control your images and colours, you should calibrate Calvin for your
daily working place only. But please don't work with a 25W weak lamp.
We recommend daylight lamps which can be delivered by any lamp
specialist – it's worth each penny!
- Be sure that your monitor has run for fifteen minutes already
at least. Keep control that your working conditions (especially light
conditions) are the same as usual (see above).
- Now start Calamus and load Calvin (as well as CPAPER.CXM) if it
has not been loaded automatically already. No create a new document
)or load a typical document). Load the module
Colour separation
(COL_SEP.CXM) if it is not loaded already.
- Call Calvin and chose the first function group. Click on the
icon
Create new calibration
, this is the very left icon in the
middle row.
This opens the calibration dialog.
- Click on the button
Gamma
. The screen turns gray and the
gamma value dialog opens:
Take your grayscale wedge print and hold him near the grayscale
wedge shown in the dialog. Now you can adjust the gamma value by
moving the little arrow below the grayscale with pressed mouse button,
until the shown grayscale wedge looks most similar to the printed one.
Alternatively, you can switch to 50% preview and adjust it with the
middle gray of the printed grayscale wedge. Close the gamma dialog
with [OK].
- Now get your printed colour wedge. Click on the Cyan colour
button. The large preview field now shows a cyan coloured area.

Hold your printed colour wedge near to it and adjust the single
colour components by moving the three sliders until the colour on the
screen is almost identical with the one of your printed Cyan colour
field. Please be most distinctive, take time, put away the control
print from time to time. It is best recommended to take short breaks
for your eyes, too. Look at something else and let your eyes
regenerate.
When your done with Cyan, continue the work with the other colours
Yellow, Magenta and Black\Key. Don't adjust the paper colour now, this
is mentioned in step 3 of this tutorial.
- Now set the option checkbox for
Separation
.
If you have created a new document or your loaded document has no
(useful) colour separation definitions, click on the button
Call
. The colour separation dialog opens. Click on the icon
Document
, please. Now the Calamus control curve editor opens.
Load your default 4c separation or, if your not familiar with
separation, the file CALVIN4C.CK7 from the package. Close control
courve editor as well as colour separation dialog with [OK]. When the
colour separation asks whether to delete subset information or not,
chose No
.
- Now you find yourselb back in Calvin's calibration dialog.
Enter a name for the profile and close the dialog with [OK].

A status bar shows the progress of the calculation for the new
profile:
Some seconds later Calvin is done and you can see the new profile
as a list entry in the Calvin function panel. It is selected already
and the monitor has been calibrated.
Now chose the entry Save profile
from the popup menu
Profile file operations
and save it with a unique name, using
the extension CPA.
- If you want this calibration (and even others which may be
shown in the list) to be loaded and activated automatically on the
next start of Calvin, switch to the second function group of the
Calvin module and call the
Settings
dialog. Check on the option
Save current list as default
and click on Save
afterwards.
Copyright © invers Software (Home)
Last updated on June 24, 2015